Single phase filter


 

Technical Parameters

 

Rated voltage:250 VAC,non-standard can be customized

Rated frequency:50Hz,non-standard can be customized

Rated current:3A~200A,non-standard can be customized

High pressure test:P/N-E2000VAC/2secP-N1100VC/2sec

Temperature range:-25℃~85℃(25/85/21)

Design basis:IEC/EN60939

Typical filter frequency:150 kHz~30MHz

 

Technical Parameters

 

Rated voltage:250 VAC,non-standard can be customized

Rated frequency:50Hz,non-standard can be customized

Rated current:3A~200A,non-standard can be customized

High pressure test:P/N-E2000VAC/2secP-N1100VC/2sec

Temperature range:-25℃~85℃(25/85/21)

Design basis:IEC/EN60939

Typical filter frequency:150 kHz~30MHz

PRODUCT

Reactor
Filter
Transformer
Power quality inspection
Reactive power compensation
Active filter
The integrated solutions for improving power quality
Customization

Easy to install single-stagefilter. Small capacitors are widely used in switching power suppies, UPS, inveters etc. Be sure to ensure good grounding for more than 50A, otherwise there is a risk of electric shock.

 

Selection table of filter

 

Filter model  

Rated current

@40℃ (A) 

Leakage current

@230VA/50Hz

Energy loss Termination

@25℃/50Hz (W) 

Termination method

 
Universal Medical use   Universal Medical use  
STS-PFI-3-2D2.3 STS-PFI-3-2D2.3A-MT 3 0.87 0.074 2.3   Insert
 
STS-PFI-6-2D3.2 STS-PFI-6-2D3.2A-MT 6 0.87 0.074 3.2   Insert 
 
STS-PFI-10-2D3.8 STS-PFI-10-2D3.8A-MT 10 0.87 0.074 3.8   Insert 
 
STS-PFI-16-2D4.7 STS-PFI-16-2D4.7A-MT 16 0.87 0.074 4.7   Insert 
 
STS-PFI-20-2D5.6 STS-PFI-20-2D5.6A-MT 20 0.87 0.074 5.6   Insert 
 
STS-PFI-30-2D8.5 STS-PFI-30-2D8.5A-MT 30 0.87 0.074 8.5   Screw
 
STS-PFI-50-2D13.3 STS-PFI-50-2D13.3A-MT 50 1.75 0.074 13.3   Screw
 
STS-PFI-100-2D30.2 STS-PFI-100-2D30.2A-MT 100 1.75 0.074 30.2  Screw
 
STS-PFI-3200-2D46.9 STS-PFI-3200-2D46.9A-MT 200 3.5 0.074 46.9 Screw
 

 

 

Typical application

 

Electrical and electronic equipment consumer goods

Home equipment

Electronic data processing equipment

Office automation and data

Communication equipment

 

 

Identification code

 

 

Dimensions

 

 

Easy to install single-stagefilter. Small capacitors are widely used in switching power suppies, UPS, inveters etc. Be sure to ensure good grounding for more than 50A, otherwise there is a risk of electric shock.

 

Selection table of filter

 

Filter model  

Rated current

@40℃ (A) 

Leakage current

@230VA/50Hz

Energy loss Termination

@25℃/50Hz (W) 

Termination method

 
Universal Medical use   Universal Medical use  
STS-PFI-3-2D2.3 STS-PFI-3-2D2.3A-MT 3 0.87 0.074 2.3   Insert
 
STS-PFI-6-2D3.2 STS-PFI-6-2D3.2A-MT 6 0.87 0.074 3.2   Insert 
 
STS-PFI-10-2D3.8 STS-PFI-10-2D3.8A-MT 10 0.87 0.074 3.8   Insert 
 
STS-PFI-16-2D4.7 STS-PFI-16-2D4.7A-MT 16 0.87 0.074 4.7   Insert 
 
STS-PFI-20-2D5.6 STS-PFI-20-2D5.6A-MT 20 0.87 0.074 5.6   Insert 
 
STS-PFI-30-2D8.5 STS-PFI-30-2D8.5A-MT 30 0.87 0.074 8.5   Screw
 
STS-PFI-50-2D13.3 STS-PFI-50-2D13.3A-MT 50 1.75 0.074 13.3   Screw
 
STS-PFI-100-2D30.2 STS-PFI-100-2D30.2A-MT 100 1.75 0.074 30.2  Screw
 
STS-PFI-3200-2D46.9 STS-PFI-3200-2D46.9A-MT 200 3.5 0.074 46.9 Screw
 

 

 

Typical application

 

Electrical and electronic equipment consumer goods

Home equipment

Electronic data processing equipment

Office automation and data

Communication equipment

 

 

Identification code

 

 

Dimensions

 

 

Energy Feedback Reactor

Reference / Implementing Standards GB1094.6-2011 Electric transformer JB9644-1999 Semiconductor electric drive reactor IEEE519 - 1992/EN6100-5-2

Harmonic filter

Reference/ lmplementing Standards IEEE519(EN - 2-5) Electromagnetic Magnetic Compatibility(EMC) EN61558-2-20 (VDE 507-2-20) Safety of Power Supply Equipment and Similar Equipment GB145493-93 Power Quality Public Power Grid Harmonic Wave

LCL filter

Reference/ lmplementing Standards GB 1094.6-2011 Reactor GB 1094.6-2011 Reactor (eqvlEC289:1987) JB 9644-1999 semiconductor electric drive reactor IEEE519-1992 GBT14549-93

EMI filter

Please see the details

Output Reactor

It is installed at the output end of the inverter, which is used to limit the capacitive charging current of the inverter and the motor connecting cable, and inactivate the voltage rise rate of PWM wave output by the inverter. When the length of motor cable exceeds a certain value, it is recommended to insert a motor reactor between the inverter and the motor, which is used to compensate the recharging current of capacitor in case of the long wires. The maximum length depends on the rated value of the frequency converter and the type of the motor cable.

Input Reactor

The input reactor can be used to provide improved overload protection for the line power supply, and to reduce the current harmonic distortion produced by the inverter. Increase the power factor of input power supply, reduce the high harmonic, and restrain the surge of frequency converter in the power supply equipment

Isolation transformer

The SG series three-phase dry-type isolation transformer is a new generation of energy-saving dry-type transformers developed and produced by our company on the basis of reference to similar international products and combined with applications. From...

DC Smoothing Reactor

DC smoothing reactor is used in the rectifying circuit to restrain the ripple pulse component after rectification and make the rectified current continuous, so as to improve the output branch waveform and guarantee the normal operation of DC equipment. The smoothing reactor is used as the series reactor in DC machine supplied by the converter, in order to eliminate the DC link in the current and voltage DC link converter; It is supposed to decouple the converter components on DC side. The power converter on DC side has high pulse circuit feedback to reduce the difference value limit, so as to limit the ring current on the connection with ring current, at the same time, limit the the rising rate of current. The smoothing reactor adopts the iron core of TEM and TET or TPK air core reactor, depending on the requirements on electromagnetic induction.

Sine wave filter

Reference / lmplementing Standards: IEEE519(EN61000-5-2) Electromagnetic compatibility (EMC) EN 61558-2-20(VDE507-2-20) Safety of power supply equipment and similar equipment GB 145493-93 Power quality, utility grid harmonics

Dv/dt filter

Reference / Implementing Standards: IEC60076-6:2007 Reactor GB1094.6-2011 Reactor (eqvIEC289:1987) JB9644-1999 Semiconductor electric drive reactor

Energy Feedback Reactor

Reference / Implementing Standards GB1094.6-2011 Electric transformer JB9644-1999 Semiconductor electric drive reactor IEEE519 - 1992/EN6100-5-2

Harmonic filter

Reference/ lmplementing Standards IEEE519(EN - 2-5) Electromagnetic Magnetic Compatibility(EMC) EN61558-2-20 (VDE 507-2-20) Safety of Power Supply Equipment and Similar Equipment GB145493-93 Power Quality Public Power Grid Harmonic Wave

LCL filter

Reference/ lmplementing Standards GB 1094.6-2011 Reactor GB 1094.6-2011 Reactor (eqvlEC289:1987) JB 9644-1999 semiconductor electric drive reactor IEEE519-1992 GBT14549-93

EMI filter

Please see the details

Output Reactor

It is installed at the output end of the inverter, which is used to limit the capacitive charging current of the inverter and the motor connecting cable, and inactivate the voltage rise rate of PWM wave output by the inverter. When the length of motor cable exceeds a certain value, it is recommended to insert a motor reactor between the inverter and the motor, which is used to compensate the recharging current of capacitor in case of the long wires. The maximum length depends on the rated value of the frequency converter and the type of the motor cable.

Input Reactor

The input reactor can be used to provide improved overload protection for the line power supply, and to reduce the current harmonic distortion produced by the inverter. Increase the power factor of input power supply, reduce the high harmonic, and restrain the surge of frequency converter in the power supply equipment

Isolation transformer

The SG series three-phase dry-type isolation transformer is a new generation of energy-saving dry-type transformers developed and produced by our company on the basis of reference to similar international products and combined with applications. From...

DC Smoothing Reactor

DC smoothing reactor is used in the rectifying circuit to restrain the ripple pulse component after rectification and make the rectified current continuous, so as to improve the output branch waveform and guarantee the normal operation of DC equipment. The smoothing reactor is used as the series reactor in DC machine supplied by the converter, in order to eliminate the DC link in the current and voltage DC link converter; It is supposed to decouple the converter components on DC side. The power converter on DC side has high pulse circuit feedback to reduce the difference value limit, so as to limit the ring current on the connection with ring current, at the same time, limit the the rising rate of current. The smoothing reactor adopts the iron core of TEM and TET or TPK air core reactor, depending on the requirements on electromagnetic induction.


Next:DC filter